tel:
+86 16651737187email:
shanyf@chinasti.comWalk-in test chamber can provide high temperature, low temperature, humidity and other environmental simulation conditions, used in high and low temperature storage test, high and low temperature cycle test, constant humidity heat test, and alternating humidity heat test with different product dimensions.
| Model | S/SH | 710A | 710B | 710C | 710D | 710E | 710F | 715B | 715C | 715D | 715E | 715F | 720B | 720V | 720D | 720E | 720F |
| Volume | m³ | 10 | 15 | 20 | |||||||||||||
| Inner Depth | mm | 2500 | 3000 | 4000 | |||||||||||||
| Inner Width | mm | 2000 | 2500 | 2500 | |||||||||||||
| Inner Height | mm | 2000 | 2000 | 2000 | |||||||||||||
| Outer Depth | mm | 2650 | 3150 | 4150 | |||||||||||||
| Outer Width | mm | 2300 | 2800 | 2800 | |||||||||||||
| Outer Height | mm | 2400 | 2400 | 2400 | |||||||||||||
| Unit Dimension | mm | 2300 x (800+550) x 2400 | 2300 x (1000+550) x 2400 | 2300 x (1200+550) x 2400 | 2300 x (1000+550) x 2400 | 2300 x (1200+550) x 2400 | 2300 x (1000+550) x 2400 | 2300 x (1200+550) x 2400 | |||||||||
| Temperature Performance Parameters | |||||||||||||||||
| Temperature Change Range | ℃ | -70~150 | |||||||||||||||
| Temperature Change Rate Range | ℃ | -55~85 | |||||||||||||||
| Temperature Change Average Rate | ℃ | 1 | 1 | 2 | 2 | 5 | 5 | 1 | 2 | 2 | 3 | 5 | 1 | 1 | 2 | 3 | 5 |
| Temperature Change Linear Rate | ℃ | 0.5 | 0.5 | 1 | 1 | 3 | 3 | 0.5 | 1 | 1 | 1.5 | 3 | 0.5 | 0.5 | 1 | 1.5 | 3 |
| Load (Aluminum ingots) | kg | 40 | 200 | 120 | 200 | 40 | 200 | 80 | 40 | 120 | 120 | 80 | 40 | 200 | 80 | 80 | 50 |
| Temperature Fluctuations | ℃ | ≤1 | |||||||||||||||
| Temperature Uniformity | ℃ | ≤2 | |||||||||||||||
| Temperature Deviation | ℃ | ±2 | |||||||||||||||
| Temperature and Humidity Climate Parameters | |||||||||||||||||
| Temperature Range | ℃ | 20-85 | |||||||||||||||
| Humidity Range | %RH | 20-98 | |||||||||||||||
| Temperature Fluctuations | ℃ | ≤1 | |||||||||||||||
| Temperature Uniformity | ℃ | ≤1 | |||||||||||||||
| Temperature Deviation | ℃ | ±2 | |||||||||||||||
| Humidity Deviation | %RH | +2/-3%RH(Humidity > 75%RH), ±5%RH(Humidity ≤ 75%RH) | |||||||||||||||
| Humidification power | kW | 10 | 15 | 20 | |||||||||||||
| Power Supply | AC380V 50Hz TN-S | ||||||||||||||||
| Power | kW | 46 | 51 | 55.5 | 78 | 99 | 114 | 55 | 66 | 61.5 | 84 | 114 | 36 | 66 | 61.5 | 84 | 114 |
| Noise | dB (A) | 75 | |||||||||||||||
| Cooling Water Flow | m³/h | 6.5 | 10 | 13 | 17 | 24 | 31 | 10 | 13 | 17 | 24 | 31 | 10 | 13 | 17 | 24 | 31 |
| Chamber Structure | All-in-one/split (Deepth not include the unit dimension) | ||||||||||||||||